Custom windings


In our own coil department we manufacture both specialized coils and new coils from defective motors.

This is particularly worthwhile in motors, for example, which have a specialized shaft and must quickly be deployed again.
The revision of a faulty motor includes the following services:

  • Remove motor
  • Remove damaged coil
  • Insulate stator in insulation class F
  • Re-wrap Stator in insulation class F, dual waterproofing
  • Clean all parts
  • Re-seat the rotor
  • Mount the motor
  • Non-destructive coil testing using Baker test instruments
  • Test according to VDE 0530
  • Perform test run